As almost all engineering formulas you only get a prediction as you can se of following tests made in different kind of corrugated and different box sizes.
Corrugated ECT in N/m
- A = 6130
- B = 5450
- C = 6130
- D = 8910
|
Corrugated |
L x W x H in mm |
Mc Kee in N |
Measurement in N |
|
A |
200x200x200 |
1672 |
2250-2900 |
|
A |
400x400x400 |
2466 |
3100-3650 |
|
B |
400x200x200 |
2406 |
2150-2500 |
|
C |
200x200x200 |
2006 |
2300-2750 |
|
C |
400x200x200 |
2709 |
2600-3100 |
|
C |
400x400x200 |
2886 |
2800-4000 |
|
C |
400x400x400 |
2506 |
3100-4000 |
|
D |
400x400x400 |
5339 |
6200-7600 |